Mains armoured cable, also known as a steel-wire armoured (SWA) cable, is a robust electrical cable designed for use in demanding environments. It consists of a protective layer of steel wires or tape, providing enhanced mechanical protection and resistance to external elements. The inner core of the cable comprises insulated conductors, typically made of copper or aluminum.
Send Inquiry

Product Introduction

Why Choose Us?

Professional Team

Liaoning Pengcheng Cable Co., Ltd. was founded in 1990. The company's R & D team is composed of experienced cable experts in the industry, and has independently developed a variety of high-tech special cable products.

Advanced Equipment

Pengcheng Cable has a number of international advanced production lines, modern factories, industrial parks of integrated wire and cable manufacturing enterprises.

Quality Control

The company's products have passed ISO9001/IATF16949 quality management system certification, ISO14001 environmental management system certification, ISO45001 Occupational health and safety management system certification, ISO10012 measurement management system certification and other 8 major management system certifications.

 

 

 

One-stop Solution

The company is mainly committed to research & development and production of flexible mineral insulated fireproof cables, mica belt mineral insulated corrugated copper sheathed cables, and new high conductivity 8000 series of anti-pressure and creep-resistant aluminum alloy core interlocking armored power cables, as well as halogen-free low-smoke flame retardant cables and ordinary wire and cable and other full range of full-specification high-quality cable products system research and development, design, manufacturing, marketing and service.

What Is Mains Armoured Cable

 

Mains armoured cable, also known as a steel-wire armoured (SWA) cable, is a robust electrical cable designed for use in demanding environments. It consists of a protective layer of steel wires or tape, providing enhanced mechanical protection and resistance to external elements. The inner core of the cable comprises insulated conductors, typically made of copper or aluminum.

4 Core Low Voltage Power Cable

4 Core Low Voltage Power Cable

NGABTLY four-core low-voltage power cable is a new generation of mineral insulated cable developed on the basis of BTTZ cable, which has the advantages of BTTZ cable and overcomes the problems and defects of BTTZ cable.

Yjv22 Power 16mm Armoured Cable Underground Electrical Wire

Yjv22 Power 16mm Armoured Cable Underground Electrical Wire

It is mainly used for temperature measurement, signal transmission and special heating in chemical industry, gold metallurgy, machinery manufacturing, power generation and scientific experiments.

Yjv32 Power Electrical Cable Amourd

Yjv32 Power Electrical Cable Amourd

Armored cable mechanical protective layer can be added to any structure of the cable to increase the mechanical strength of the cable, improve the anti-erosion ability, is designed for vulnerable to mechanical damage and extremely vulnerable to erosion of the area of wire and cable.

600 1000v Armoured Cable

600 1000v Armoured Cable

YTTW armored cable This product is suitable for transmission of power lines with rated voltage 0.6/1KV and below. Fire retardant cable YTTW flame retardant characteristics in line with GB/T12666 flame retardant standard.

Armoured 3 Core Power Cable

Armoured 3 Core Power Cable

Armored three-core power cable is processed by a unique process, because the conductor of the cable adopts mature stranded technology, the sheath is processed by a special process of copper soft sheath, with mechanical impact resistance and flexible bending characteristics.

Armoured Power Cable With Ethernet

Armoured Power Cable With Ethernet

RTTYZ 0.6/1kV mineral cable is suitable for rated voltage 0.6/1kV excellent fire performance, smokeless and non-toxic when burning, the insulation is made of inorganic materials.

Mains Armoured Cable

Mains Armoured Cable

RTTZ main armored cable has the characteristics of mechanical impact resistance and flexible bending, the use of flame retardant minerals and copper conductors, can be flame retardant, 0.6/1kV mineral cable is suitable for rated voltage 0.6/1kV excellent fire performance.

 
Mains Armoured Cable Sizes
 

The size of mains armoured cable you choose is important for the safety, efficiency, and reliability of your electrical installation. Mains armoured cables come in a variety of sizes, which are determined by the cross-sectional area of the internal conductors measured in square millimetres (mm²).

01/

1.5 mm² & 2.5 mm²

Ideal for lighting circuits and small power tools in both residential and commercial settings.

02/

4 mm² to 6 mm²

Suitable for larger lighting installations, power outlets in homes, and outdoor lighting that requires higher current.

03/

10 mm² to 16 mm²

Often used for connections to heavy-duty electrical appliances, small industrial machinery, and large heating units.

04/

25 mm² and above

Reserved for high-load applications, including main power supply lines, industrial setups, and large electrical machinery.

Applications of Mains Armoured Cables

 

Underground installations

Mains armoured cables are commonly used for underground installations due to their ability to withstand the harsh conditions found in soil. They provide excellent protection against moisture, chemicals, and physical damage, making them ideal for applications such as underground power distribution, street lighting, and residential wiring.

 

Outdoor lighting

In outdoor lighting systems, mains armoured cables offer exceptional durability and weather resistance. Whether it's for garden lighting, pathway illumination, or security lighting, mains armoured cables ensure reliable power supply while safeguarding against environmental factors like rain, uv radiation, and temperature fluctuations.

 

Industrial and construction sites

Industrial and construction environments often involve heavy machinery, equipment, and rigorous operations. Mains armoured cables are extensively used in these settings to ensure the safe and uninterrupted supply of electricity. They are capable of withstanding high mechanical stress, making them suitable for power distribution in factories, warehouses, construction sites, and other demanding industrial applications.

 

Power distribution networks

Mains armoured cables play a crucial role in power distribution networks, both indoors and outdoors. They are frequently employed in substations, transformer stations, and electrical panels to transmit electricity over long distances. Mains armoured cables provide protection against accidental damage, which is essential for maintaining uninterrupted power supply to residential, commercial, and industrial areas.

 

Hazardous locations

Certain environments, such as chemical plants, oil refineries, and mines, present hazardous conditions due to the presence of flammable substances or explosive atmospheres. Mains armoured cables with specific certifications, such as flame-retardant or explosion-proof properties, are used to mitigate the risk of electrical incidents in these settings. These cables are designed to contain any potential sparks or heat generated, ensuring the safety of personnel and property.

Advantages of Mains Armoured Cable
 

Enhanced protection

The metal or polymer armour provides superior protection against mechanical damage, moisture, and external hazards, ensuring the longevity and reliability of the cable.

Durability

Mains armoured cables are built to withstand harsh conditions, including exposure to chemicals, oils, and extreme temperatures, making them ideal for industrial and outdoor applications.

Rodent resistance

The armoured construction deters rodents and pests from chewing or damaging the cable, reducing the risk of downtime and maintenance costs.

Suitable for burial

Mains armoured cables can be buried directly in the ground or installed in conduits, trenches, or cable trays, offering versatility in outdoor and underground installations.

How to Lay Mains Armoured Cable Correctly
 

When laying a mains armoured cable underground, the armoured electrical cable must be laid out at a sufficient depth to avoid any potential damage or disturbance. It is better to consider increasing the depth of direct burial underground or provide additional protection for the mains armoured cable to ensure security.


It is a fact that standards do not state a single minimum depth, which is why it is necessary to make sure that the armoured electric cable will not be affected by typical activity.


A minimum installation depth that's followed by all professionals is 450mm underground. This depth increases to 600mm for mains armoured cables in locations where there is a higher chance for any potential disturbance.


If the armoured electrical cable is installed directly into the ground, the cable should be surrounded by sharp sand to make sure it is protected against any damage to the sheath or insulation. Another precaution that can be taken is the use of electrical warning tape – This can be placed above the sand to indicate that there is an armoured electrical cable present below.


In the case of a mains armoured cable being installed within a pipe, it is crucial to ensure that it is completely watertight to prevent ingress of any kind.


The armoured mains cable should also be earthed regardless of whether the armouring is being used as a protective conductor or not. What this does is make sure that the automation disconnection of supply (ADS) requirements are adhered to.

600 1000v 铠装电缆

Do You Need to Earth Mains Armoured Cable

 

 

The short answer is yes, and here's why:

 

Safety first: Earthing is essential for the safety of both individuals and equipment. A mains armoured cable may become live due to faults or insulation breakdowns. If not properly earthed, this could lead to electric shock hazards for anyone coming into contact with the cable or surrounding structures.

 

Fault current dispersal: In the event of a fault, such as a short circuit, the excess current needs a path to dissipate. Earthing provides a low-resistance path for fault currents to flow safely into the ground, preventing damage to the cable itself and reducing the risk of fire.

 

Voltage stabilization: Earthing helps stabilize the voltage levels in the electrical system. Without proper earthing, voltage fluctuations could occur, leading to equipment malfunction and potential damage.

 

Compliance: Many electrical codes and regulations mandate the earthing of cables for safety and operational reasons.

How to Cut Mains Armoured Cable

 

Mains Armoured Cable

There are several different tools you can use to cut mains armoured cable. The best option is to use dedicated cable cutters which are designed with this task in mind.


Follow these steps to use cable cutters safely and efficiently:
● Accurately measure the cable length required and mark the outer sheath at the cutting point
● Adjust the cutters' blade depth to ensure the correct depth for cutting through the armour
● Position the cable in the cutters' wire guide, align with the marked cutting point and secure it in place
● Carefully make the cut
● Remove the newly cut cable from the cutters

Taking a Closer Look Inside of Mains Armoured Cable

 

 

Crafting mains armoured cables involves several intricate processes to ensure their durability and reliability.

 

Wire drawing: Crafting of mains armoured cable starts by pulling copper or aluminum rods through a series of dies. This makes the rods thinner and longer.

 

Annealing: Next, it is needed to make the wires flexible, so the ductility and malleability of wire is increased.

 

Twisting & stranding: Multiple conductors are twisted and stranded to get desired cross- sectional area.

 

Insulation: Conductors are insulated with high quality XLPE/PVC..

 

Laying up: After insulation, the insulated cores are laid up on the laying up machine.

 

Inner sheath: Another layer is added with high quality PVC.

 

Armouring: The cable is made even tougher by wrapping it with galvanized steel wires or strips.

 

Outer sheath: A strong outer layer of PVC with marking is added to protect the cable from all kinds of rough conditions like weather and chemicals.

 

Quality check: Before we use the cables, it is made sure everything is perfect by inspecting them carefully.
Mains armoured cables stand out as essential components for powering various electrical systems, offering unmatched protection, reliability, and durability.

 
Our Factory

Liaoning Pengcheng Cable Co., Ltd. was founded in 1990, located in the northeast center of Shenyang & Tieling business district, is the comprehensive strength of the forefront of wire and cable manufacturing enterprises. Pengcheng Cable has a number of international advanced production lines, modern factories, industrial parks of integrated wire and cable manufacturing enterprises. The company is now located in Xintaizi Industrial Park, Liaoning Province, covering an area of nearly 150 acres, the factory area more than 50 acres. The company is mainly committed to research & development and production of flexible mineral insulated fireproof cables, mica belt mineral insulated corrugated copper sheathed cables, and new high conductivity 8000 series of anti-pressure and creep-resistant aluminum alloy core interlocking armored power cables, as well as halogen-free low-smoke flame retardant cables and ordinary wire and cable and other full range of full-specification high-quality cable products system research and development, design, manufacturing, marketing and service. Pengcheng products are widely used in smart grid, energy power, green building, smart factory and hospital and other fields. Currently has a number of valid patents.

product-1-1
product-800-462
 
Our Certificate

The company's products have passed ISO9001/IATF16949 quality management system certification, ISO14001 environmental management system certification, ISO45001 Occupational health and safety management system certification, ISO10012 measurement management system certification and other 8 major management system certifications. As well as the national industrial product production license, national mandatory product certification (3C certification), PCCC certification and China Quality CQC certification, flame retardant label certification, fire retardant label certification and other certifications.

product-1-1

 

FAQ

Q: What is the difference between mains armoured cable and normal cable?

A: Mains armoured cable has an additional level of protection made of metal, protecting it from physical damage, moisture, and other environmental factors. There is no external protective layer in unmains armoured cable, which makes it more vulnerable to damage from external factors.

Q: What are the different types of armored cables?

A: There are two types of mains armoured cables: aluminum wire armour and steel wire armour. Three core steel wire mains armoured cable is mainly used for Single phase circuits, which must have earth connections.

Q: Where is mains armoured cable required?

A: Mains armoured cable is designed for use in situations where electrical wiring faces a higher risk of mechanical damage, interference, or exposure to harsh environmental conditions. It's a popular choice for ensuring safety and longevity in both commercial and residential settings.

Q: How do you cut mains armoured cable?

A: While there are a few different tools you can use to cut mains armoured cable, such as side cutters or a hacksaw, the best option is to use dedicated cable cutters specifically designed for the task.
Before cutting the cable, you should accurately measure the cable length required and mark the outer sheath at the cutting point. Then, adjust the cutters' blade depth correctly to allow it to cut through the armour. You should position the cable in the cutters' wire guide and align it with the cutting point you marked. Secure it in place and then carefully make the cut.

Q: Why are mains armoured cables not used in house wiring?

A: Primary concerns are the relative conductivity of the armouring compared to the cores (which reduces as the cable size increases) and reliability issues.

Q: How do I know if my cable is armoured?

A: The code designation method of armored electrical cable is to add a number after the ordinary cable symbol. The first one: "2" means double steel tape armor; the second one: "2" means PVC sheath.

Q: How do I know what size mains armoured cable to get?

A: Here's how to select the right mains armoured cable thickness for the job:
Calculate the total load: Sum the power ratings (in watts) of all devices that will be connected to the cable.
Consider the length: For longer runs, opt for a thicker cable to mitigate voltage drop and ensure efficient power delivery.

Q: Which mains armoured cable do I need?

A: Quick cable calc suggests 10mm SWA for a load of 50A 33M away. Going with 16mm gives you the safety net of more power if you need it. The distance of the circuit (33M) needs to be allowed for in sizing the cable.

Q: How far underground does mains armoured cable need to be?

A: If you'll be running the cable underground then you'll need to lift the floor to make enough space and depth. Around 500mm of depth is recommended as a minimum. If you're putting the cable through a vegetable patch, it will need to be at least 600mm deep.

Q: Can you leave mains armoured cable above ground?

A: Of course, you can, but the reason for specifying the extra cost of a mains armoured cable is to protect it from damage when it is run underground out of sight and may be hit by a spade. For the same reason, there should be marker tape buried just below the surface to indicate that there is a mains armoured cable buried deeper.

Q: What is the lifespan of mains armoured cable?

A: Mains armoured cables have a long lifespan due to the durability of the cables. They can last up to 20 to 50 years.

Q: Can mains armoured cable be used in residential?

A: Residential construction primarily uses three types of wiring, Non-Metallic (NM) cable being the most common; followed by BX (also know as Armor Clad, or Flexible Metal Conduit), and individual conductors run inside conduit.

Q: Does mains armoured cable need to be glanded?

A: In order to correctly provide the path to earth, and securely terminate the cable into an enclosure, correct SWA glands must be used.

Q: Can mains armoured cable be joined?

A: 10mm – 16mm mains armoured cable Joints are for joining multiple lengths of cable together. For example, they're great for repairing a length of cable or adding another smaller diameter cable to a run.

Q: Do you need to earth a mains armoured cable?

A: The short answer is yes, and here's why:
● Safety First: Earthing is essential for the safety of both individuals and equipment. A mains armoured cable may become live due to faults or insulation breakdowns. If not properly earthed, this could lead to electric shock hazards for anyone coming into contact with the cable or surrounding structures.
● Fault Current Dispersal: In the event of a fault, such as a short circuit, the excess current needs a path to dissipate. Earthing provides a low-resistance path for fault currents to flow safely into the ground, preventing damage to the cable itself and reducing the risk of fire.
● Voltage Stabilization: Earthing helps stabilize the voltage levels in the electrical system. Without proper earthing, voltage fluctuations could occur, leading to equipment malfunction and potential damage.
● Compliance: Many electrical codes and regulations mandate the earthing of cables for safety and operational reasons. Failing to adhere to these standards could result in legal and regulatory consequences.

Q: How to properly earth a mains armoured cable?

A: Now that we understand the importance of earthing, let's explore the proper steps to earth a mains armoured cable effectively:
Selecting the earthing method: There are a few methods to earth mains armoured cables, including direct earthing, earthing through the cable armor, or using separate earth wires. The method you choose should be based on factors such as the application, environment, and local regulations.
Grounding electrodes: Proper grounding electrodes, such as grounding rods or plates, need to be installed. These electrodes ensure a reliable connection between the cable's earth conductor and the earth's ground.
Connection integrity: The connection between the cable's earth conductor and the grounding electrode must be secure and low-resistance. Proper clamps, connectors, and exothermic welding are commonly used to achieve this.
Regular maintenance: Earthing systems should be regularly inspected and maintained to ensure their effectiveness. Corrosion, loose connections, or other issues can compromise the system's performance.
Professional expertise: It's highly recommended to involve a certified electrician or electrical engineer when designing and installing the earthing system. Their expertise will ensure compliance with regulations and best practices.

Q: What is the difference between mains armoured cable and SWA cable?

A: Mains armoured cable, also known as steel wire armoured (SWA) cable, or booklet mains armoured cable, is a low voltage (LV) power cable or control cable that is designed for use in mains supply at a maximum 600/1000 V.

Q: Where are mains armoured cables permitted to be installed?

A: Mains armoured cable can be used for both exposed and concealed locations. mains armoured cable is not permitted in locations where it will be subjected to physical damage or corrosive fumes. mains armoured cable cannot be used for direct burial in earth.

Q: Do you need to protect mains armoured cable?

A: The 500mm of cable just above ground level may require protection from being kicked or hit from other movable objects. Buried cables also must be protected from being crushed, this is usually done by laying the mains armoured cable in a bed of sand so that stones are not pressed into the outer sheathing of the cable.

Q: How do you pull mains armoured cable through ducting?

A: The method works as follows:
Tie the string: Tie a strong string to a long, inflexible rod.