Hey there! As an armoured cable supplier, I've seen a whole bunch of issues with these cables over the years. Armoured cables are super important in lots of electrical applications because they offer protection to the conductors inside. But just like any other product, they can have their fair share of problems. Let's dive into the common faults of armoured cables.
1. Mechanical Damage
One of the most common issues we come across is mechanical damage. Armoured cables are tough, no doubt about it, but they're not invincible. Things like digging, construction work, or even animals can cause physical harm to the cables. For instance, during a construction project, if the construction workers aren't careful, they might accidentally hit the cable with heavy equipment. This can lead to dents, cuts, or even breaks in the armour and the conductors inside.
If the armour gets damaged, it loses its ability to protect the internal conductors from external factors like moisture and physical impacts. And if the conductors are damaged, well, that spells trouble for the electrical system. You might start experiencing power outages, short - circuits, or inconsistent electrical flow.
To prevent mechanical damage, proper installation is crucial. The cables should be buried at the right depth and clearly marked. If you're using armoured cables in an industrial setting, having them installed in conduit or trays can also provide an extra layer of protection.


2. Corrosion
Corrosion is another big headache when it comes to armoured cables. The armour is usually made of metal, and metals are prone to rust and corrosion when exposed to certain environments. For example, in areas with high humidity, salty air (like near the sea), or acidic soil, the armour can start to corrode over time.
When corrosion sets in, it weakens the armour. The rust can also cause the armour to expand, which may put pressure on the internal conductors. This can lead to insulation damage and eventually, electrical problems.
We offer different types of armoured cables, such as the XLPE Insulated Underground Power Cable that have better resistance to corrosion. But even with these cables, it's important to inspect them regularly. If you notice any signs of rust or corrosion, it's a good idea to take action right away. You might need to clean the affected area and apply a protective coating to prevent further corrosion.
3. Insulation Failure
The insulation in armoured cables is what keeps the electrical current flowing safely through the conductors and stops it from leaking out. However, insulation failure can occur due to several reasons.
Age is one factor. Over time, the insulation material can degrade due to heat, moisture, and electrical stress. If the cable is operating in a high - temperature environment, the insulation can become brittle and crack. Moisture can also seep into the insulation, reducing its insulating properties.
Another common cause of insulation failure is improper installation. If the insulation is damaged during installation, it can lead to premature failure. For example, if the cable is bent too tightly, it can cause the insulation to crack.
One of our popular products, the Yjv22 Power 16mm*5 Armoured Cable, has high - quality insulation. But it still requires proper handling and maintenance to ensure the insulation remains in good condition. Regular insulation resistance testing can help detect early signs of insulation failure, allowing you to take preventive measures.
4. Termination and Jointing Problems
Termination and jointing are critical parts of any electrical installation. In armoured cables, if the termination or jointing is not done correctly, it can lead to all sorts of issues.
Poor workmanship is a major culprit. If the connections are not tight enough, it can cause resistance at the joints. This resistance generates heat, which can damage the insulation and lead to a short - circuit. Also, if the sealing at the termination points is not proper, moisture can enter the cable, causing corrosion and insulation problems.
It's essential to use the right tools and follow the manufacturer's instructions when terminating or jointing armoured cables. Our team can provide you with detailed guidance on how to do this correctly. We also offer the Mains Armoured Cable which comes with clear instructions for proper termination and jointing.
5. Overloading
Overloading is a common problem in electrical systems, and armoured cables are not immune to its effects. If the cable is carrying more electrical current than it's rated for, it can overheat.
Overheating can cause the insulation to melt, which not only leads to insulation failure but can also be a fire hazard. It can also damage the armour and the conductors inside.
To avoid overloading, it's important to size the cables correctly based on the electrical load. You should also regularly monitor the electrical system to ensure that the cables are not being overloaded.
Wrapping Up
So, there you have it - the common faults of armoured cables. While these issues can be a pain, they're also preventable with proper installation, maintenance, and regular inspections.
As an armoured cable supplier, we're here to help you find the right cable for your needs and provide you with all the support you need. If you're having any issues with your armoured cables or if you're in the market to purchase new ones, don't hesitate to get in touch. We can offer you high - quality products, expert advice, and assistance with installation and maintenance.
Let's work together to ensure your electrical systems are safe and reliable. Just reach out to us, and we'll start the conversation about how we can meet your armoured cable requirements.
References
- IEEE Standards for Electrical Insulation in Cables
- National Electrical Code (NEC) for Cable Installation Guidelines